TECHNICAL DATA 
GAS TYPE:   NATURAL GAS 
GAS PRESSURE:  20mbar 
CONNECTION     8mm TUBE 
INJECTOR manual control: CAT 82/420 BRAY 
INJECTOR remote control: CAT 82/400 BRAY 
HEAT INPUT 6.5kW HIGH 
 4.1kW LOW 
CAT 12H DATA BADGE ON FRONT BOTTOM SECTION OF APPLIANCE 
IMPORTANT NOTES 
THIS APPLIANCE IS FITTED WITH AN ATMOSPHERE SENSING DEVICE 
AND CAN ONLY BE FITTED IN CONJUNCTION WITH THE FOLLOWING 
FLUES. 
CONVENTIONAL BRICK OR STONE CHIMNEY. 
A PRE CAST FLUE CONFORMING TO BS 1289 PT 1 
OR A METAL FLUE BOX CONFORMING TO BS715 
A NON COMBUSTIBLE HEARTH MUST BE PROVIDED TO COMPLY WITH 
THE BUILDING REGULATIONS OR A SUITABLE PROPRIETARY FIRE 
SURROUND WITH 100 DEGREES C RATING. 
THE CHIMNEY OR FLUE (UNLESS NEW) MUST BE SWEPT BEFORE 
INSTALLATION, IF IT HAS BEEN USED FOR SOLID FUEL 
INSTALLER 
THIS APPLIANCE MUST BE INSTALLED BY A COMPETENT PERSON  
IE. A C.O.R.G.I. REGISTERED INSTALLER(IN GREAT BRITAIN) IN 
ACCORDANCE WITH THE 
CURRENT EDITION OF THE GAS SAFETY (INSTALLATION AND USE) 
REGULATIONS OR THE RULES IN FORCE. FAILURE TO DO SO COULD 
LEAD TO PROSECUTION. 
VENTILATION GREAT BRITAIN 
NO SPECIAL VENTILATION BRICKS OR VENTS ARE NORMALLY 
REQUIRED INTO THE ROOM CONTAINING THE APPLIANCE, PROVIDED 
NORMAL ADVANTAGEOUS ROOM VENTILATION EXISTS, THE 
INSTALLER MUST SATISFY THIS POINT BY A MANDATORY SPILLAGE 
TEST. 
IRELAND. PURPOSE PROVIDED VENTILATION MUST BE PROVIDED AND 
MUST HAVE A MINIMUM FREE AREA OF 100CM
2 IN ACCORDANCE WITH 
I.S.813 DOMESTIC GAS INSTALLATIONS ISSUED BY THE NATIONAL 
STANDARDS AUTHORITY OF IRELAND. 