Technical data
ISSUE 2 
15
USERS INSTRUCTIONS FOR RUBY GAS APPLIANCE 
 YOUR RUBY GAS APPLIANCE IS A DECORATIVE LIVE FUEL EFFECT GAS 
FIRE ,DUE TO ITS NEWNESS THE FIRE MAY GIVE OFF SLIGHT SMELL FOR 
A SHORT PERIOD AFTER INSTALLATION .THIS IS QUITE NORMAL AND 
WILL DISAPPEAR AFTER A FEW HOURS OF OPERATION. 
THE APPLIANCE TO WHICH THESE INSTRUCTIONS APPLY MUST BE 
INSTALLED BY A COMPETENT PERSON(EG. A C.O.R.G.I MEMBER IN 
ACCORDANCE WITH THE CURRENT EDITION OF THE GAS SAFETY 
INSTALLATIONS AND USE REGULATIONS OR THE RULES IN 
FORCE)APPROVED BY THE HEALTH AND SAFETY EXECUTIVE AND 
MUST BE IN ACCORDANCE WITH THE INSTALLATION AND SERVICING 
INSTUCTIONS SUPPLIED. 
SERVICING SHOULD BE CARRIED OUT REGULARLY BY A COMPETENT 
PERSON ( EG A C.O.R.G.I MEMBER)IN ACCORDANCE WITH THE CURRENT 
EDITION OF THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS 
OR THE RULES IN FORCE.TO ENSURE THE CORRECT AND SAFE 
OPERATION OF THE APPLIANCE .DEBRIS SHOULD ALSO BE REMOVED 
FROM BEHIND THE APPLIANCE AT REGULAR INTERVALS. 
BEFORE INSTALLATION OF THE APPLIANCE THE CHIMNEY MUST BE 
SWEPT AND THEN INSPECTED REGURLARLY TO ENSURE THAT IT 
REMAINS FREE OF OBSTRUCTION. 
A FIRE GUARD COMPLYING TO BS8423 ,MUST BE FITTED IF THE ROOM 
WILL BE OCCUPIED BY YOUNG CHILDREN THE ELDERLY ,OR INFIRM 
PEOPLE. ON NO ACCOUNT MUST ANY RUBBISH BE THROWN ON TO THE 
FIRE OR THE LAYOUT OF THE FIREBED DISTURBED. 
OPERATING INSTRUCTIONS. 
THE APPLIANCE DATA BADGE IS POSITIONED ON THE FRONT BOTTOM SECTION 
OF THE APPLIANCE AND CARIES THE CONTROL KNOB POSITIONS.THE FULL 
LIGHTING PROCEDURE IS AS FOLLOWS. 
1.PUSH CONTROL KNOB IN AS FAR AS POSSIBLE ON GAS CONTROL 
2.TURN KNOB ANTICLOCKWISE TO IGNITION POSITION STILL KEEPING KNOB IN 
AS FAR AS POSSIBLE. 
3.THE IGNITION BUTTON WILL IGNITE THE PILOT WITH THIS OPERATION KEEP 
THE KNOB PRESSED IN FOR 15 SECONDS.IF THE PILOT FAILS TO LIGHT TURN 
THE CONTROL KNOB CLOCKWISE TO THE OFF POSITION, WAIT 3 MINUTES AND 
REPEAT THE PROCEDURE 
4.WHEN THE PILOT FLAME IS ALIGHT THE CONTROL KNOB SHOULD BE ALLOWED 
TO SPRING OUT SLIGHTLY.TURN THE KNOB FULLY ANTICLOCKWISE TO THE HIGH 
POSITION.THE PILOT FLAME WILL THEN IGNITE THE MAIN BURNER.THE PILOT 
FLAME CAN BE VIEWED TO THE RIGHT OF THE FIRE JUST BEHIND THE FRONT 
LOG SET 
5.THE APPLIANCE CAN BE ADJUSTED BETWEEN HIGH AND LOW BY MOVING THE 
CONTROL KNOB TO SUIT,THE KNOB WILL NEED TO BE DEPRESSED SLIGHTLY TO 
MOVE FROM LOW HIGH AND IGNITION. 
6.TO TURN THE FIRE OFF,DEPRESS THE KNOB SLIGHTLY AND TURN IT TO 
PILOT POSITION. 
7.TO COMPLETELY EXTINGUISH THE FIRE DEPRESS THE KNOB SLIGHTLY AND 
TURN TO OFF POSITION. 
8.SHOULD THE SPARK IGNITION FAIL TO OPERATE.TURN THE CONTROL KNOB TO 
THE OFF POSITION AND WAIT 3 MINUTES.TURN THE KNOB TO THE IGNITION 
POSITION AND THEN LIGHT THE PILOT WITH A TAPER.”LIGHTING THE PILOT 