Technical data
"B"
INJECTOR
LOCKNUT
RE ASSEMBLE IN REVERSE ORDER 
TURN ON GAS SUPPLY. CHECK FOR SOUNDNESS AND RECOMMISION 
THE FIRE. 
REPLACEMENT OXY PILOT ASSEMBLY 
DISCONNECT FIRE AT INLET ELBOW 
REMOVE FIRETRAY 
DISCONNECT THERMOCOUPLE AT GAS VALVE 
DISCONNECT GAS CONNECTION FROM PILOT ASSEMBLY 
REMOVE IGNITOR LEAD FROM PILOT ASSEMBLY 
UNDO SCREWS SECURING OXY PILOT TO FIRETRAY 
RE-ASSEMBLE IN REVERSE ORDER 
TURN ON GAS SUPPLY,CHECK FOR SOUNDNESS AND RE-COMMISION 
APPLIANCE 
CLEANING 
BEFORE CLEANING ANY PART OF THE FIRE ,ENSURE THAT THE GAS IS 
TURNED OFF AND FIRE IS COOL. 
BLACK PAINT 
USE ONLY CLEAN DAMP CLOTH ,DO NOT USE ANY CLEANING AGENTS 
BRASS TRIM/CHROME 
USE BRASSO,OR CHROME CLEANER ENSURING YOU REMOVE THE 
BRASS TRIM FROM THE APPLIANCE BEFORE CLEANING 
IMPORTANT 
THE PAINT AND BRASS FINISH ARE DURABLE BUT WILL BE DAMAGED 
IF PLASTER,CEMENT,OR WALLPAPER PASTE COMES IN CONTACT WITH 
IT 
COALS AND CERAMICS 
IF FOR ANY REASON IT IS NECCESARY TO REMOVE CERAMIC 
PARTS,THEN BEFORE REPLACEMENT THE BURNER SHOULD BE 
CHECKED THAT NO PARTICLES HAVE DEPOSITED ON THE BURNER 
AND IF NECCESARY VACUUM THEM CAREFULLY,THEN REFER TO 
INSTRUCTIONS FOR REPLACING CERAMICS. 
CERAMICS SHOULD BE CLEANED BY SHAKING ANY DEBRIS 
NO BRUSHING OR VACUUMING SHOULD BE PERFORMED . 
INSTALLER SPARE PARTS 
FUEL BED RUBY001 MAIN MATRIX RUBY002 
FRONT FIBRE RUBY 003 INSTUCTIONS RUBY 004 
 TRIM RUBY 005 ODS COMPLETE RUBY 006 
GAS VALVE RUB007 
INJECTOR REMOTE CONTROL RUBY007 CAT 82/400 
ISSUE 2 
13
INJECTOR MANUAL CONTROL RUBY008 CAT 82/420 