Service manual
TABLE I - I 
DESIGN DATA 
COOLING UNIT 
Overall cabinet dimensions:  CR-2    CR-UC2 
 Height   24”  20” 
 Width  20”  20” 
 Depth  22”   20” 
Weights: 
 Shipping  160   160   
 Dry weight  135   135 
 Operational Weight 250   250 
 Ice Bank  25   25 
Capacities: CR-2   
  Unit water bath (no ice bank)    9 gallons 
  Refrigerant requirement (R-134-A)     250 grams 
  Ambient operating temperature    40 F to 100 F. 
Capacities: CR-UC2   
  Unit water bath (no ice bank)    9 gallons 
  Refrigerant requirement (R-134-A)     250 grams 
  Ambient operating temperature    40 F to 100 F. 
Electrical Requirements: The cooling unit requires a 115 VAC, single phase, 60 Hertz 
 Power circuit. 
   CR-2  CR-UC2  
 Ampacity   14.9  14.9 
  Condensing Unit     6.9   6.9 
  Water/Recirc. Pump Motor   6.2   6.2 
  Agitator     .8   .8 
Water Filter Required: Everpure QC71 Twin (EV9272-22) with (2) 4CB5K filters (EV9617-36) or 
(2) 4FC (EV9692-21), Coldrink MC Twin (EV9328-02) or LVPO-F1 (94-751-00). 
  Pressure 
Incoming Water Pressure Regulator (Optional)  25 – 65 
C02 High Pressure Regulator (Carbonated units only) PSI  55 – 75 
DISPENSING VALVES Ambient Operating Temperature  32 F to 100 F 
  Electrical Requirements: Operating Voltage  24VAC, 6Ohz 
3 