Service manual
TROUBLE SHOOTING 
IMPORTANT: Only qualified personnel should service the SCR unit and components.
WARNING: To avoid personal injury and or property damage, always disconnect electrical power, 
shut off plain water and
CO2 supplies before starting any repairs. If repairs are to be made to the 
carbonated water system, bleed carbonated water system pressure before proceeding. If repairs are 
to be made to syrup system, remove quick disconnects from syrup tanks, or remove
QCD from BIB, 
then bleed system pressure before proceeding.
CARBONATOR 
Trouble 
Probable Cause 
Remedy 
Water pump 
motor will not 
operate
1. 
2. 
3. 
4. 
5. 
Inoperable water pump/ motor. 
Overheated motor (cut off by 
thermal overload protector).
Electrode inside carbonator tank 
defective.
L.L.C. assembly Inoperable.
Loose electrical connection 
and/or open electrical circuit.
Defective pump protector, S-103 
1. 
2. 
3. 
4. 
5. 
Replace water pump/ motor. 
Check for proper line voltage. 
Allow motor
 time to cool. 
Replace carbonator tank 
electrode.
Replace L.L.C. assembly.
Tighten connection and/or repair 
open circuit. Check line voltage. 
Replace pump protector 
Water pump 
motor will not 
shut off
1. 
2. 
3. 
4. 
5. 
Defective water pump. 
Electrode inside carbonator tank 
defective.
L.L.C. assembly inoperable.
Loose electrical connection and 
or open electrical circuit.
Carbonated water leak. 
1. 
2. 
3. 
4. 
5. 
Replace water pump. 
Replace carbonator tank 
electrode.
Replace L.L.C. assembly.
Tighten connection and or repair 
open ground circuit.
Find and repair leak. 
Water Pump 
motor will not 
shut off and 
pressure relief 
engaged 
1. 
2. 
Electrode inside carbonator does 
not sense ground.
L.L.C. assembly inoperable.
1. 
2. 
Replace defective electrode or 
check and tighten ground 
connection at control box.
Replace L.L.C. assembly.
Short cycling of 
water pump 
motor
1. 
2. 
3. 
Ground connection loose or 
disconnected.
Electrode inside carbonator tank 
defective.
Carbonated water leak in system. 
L.L.C. assembly inoperable. 
1. 
2. 
3. 
Attach or tighten ground 
connection.
Replace carbonator tank 
electrode.
Repair carbonated water leak. 
Replace L.L.C. control assembly. 
Water pump 
capacity to low 
1. 
2. 
3. 
4. 
Inlet water volume supply to low. 
Water
 motor/pump worn out. 
Kinked or restricted water supply 
line.
Foreign object in water pump or 
restriction to water pump. 
1. 
2. 
3. 
4. 
Increase diameter of supply line, 
install holding tank.
Replace water pump.
Clear or replace restricted water 
supply 
line. 
Clear restrictions and check pump 
strainer for debris. 
Water pump 
operates but 
water pump 
does not pump 
1. 
2. 
3. 
4. 
Water supply to low or turned off. 
Inoperative water pump.
Water supply filter clogged.
Water pump strainer clogged. 
1. 
2. 
3. 
4. 
Inlet water supply must be a 
minimum of 3/8”.
Replace water Pump.
Replace filter.
Clean water pump strainer.
42 