Service manual

SANITIZING PROCEDURES
Your local health department rules and general area cleanliness should determine the frequency at which
the unit should be sanitized.
EQUIPMENT REQUIRED:
When using an Everpure Water filter system, use the JT Flushing/Sanitizing Cartridge (EV9608-00) and
Plug, instructions included with cartridge.
1. Fill JT cartridge with sanitizing agent and install into the last position in filter manifold, plug front
position with filter plug.
2. Turn the water back on and the CO2 off.
3. Pull valves on Crysalli to draw water and sanitizer through into another bucket.
4. Flush each line for at least 1 minute (hold both faucets open and dispense into a bucket) until
water consistency and clarity changes back (flush until free of detergent), continue pulling water
for to thoroughly flush out.
5. Turn water back off and replace JT cartridge and Plug with new Everpure water filters and flush
them.
6. Dry the JT Cartridge and replace back in storage for use next time.
Manual cleaning (to be done by service tech):
1. Stainless Steel containers (product tanks), or large volume container.
2. CO2 Supply if applicable (Same as used with dispensing unit).
3. Cleaning Agent.
4. Sanitizing Solution.
5. Phenolphthalein.
NOTE: One recommended cleaning agent and sanitizing agent is manufactured by:
MT. HOOD CHEMICAL CORP.
4444 N.W. Yeon Avenue
Portland, Oregon 97210
Trade names are:
CROWN - 12.5% SODIUM HYPOCHLORITE BLEACH
Use STAR at 18 oz. per 1 gallon of water yields 2% Sodium Hydroxide Solution.
1. Visually inspect valve by removing nozzle and inspecting nozzle and valve cavity. Clean nozzle with
cleaning agent, then sanitizing solution, then with potable water. Inspect valve cavity and if dirty
clean with soft bristle brush. Clean exteriors of valve with a soft clothe and warm water. Replace
valve nozzle then go to step #3.
2. Disconnect water inlet line at a point in the exposed tubing. Leaving enough length to place in a
bucket.
3. Put inlet tubing in a bucket full of water and sanitizer.
4. Turn unit on and pull product from both valves into another bucket to discard.
5. Run sanitizer through until empty.
6. Replace bucket with clean rinse water and run through system.
7. Reconnect inlet water line and turn the water back on.
8. Taste the beverage to verify that there is no off taste.
41