Service manual
TABLE OF CONTENTS (cont’d) ................................................................ PAGE
CR-2 CABINET MAINTENANCE……………………………………………………...34
CLEANING CONDENSER COIL ......................................................................... 34
CHECKING/CHANGING WATER BATH ............................................................. 35
WATER PUMP MAINTENANCE ......................................................................... 36
CARBONATOR MAINTENANCE ........................................................................ 37
SERVICING CHECK VALVES ............................................................................. 37
REPLENISHING CO2 SUPPLY ........................................................................... 40
CHANGING WATER FILTER CARTRIDGE ........................................................ 40
ADJUSTMENT OF CO2 REG .............................................................................. 40
SANITIZING PROCEEDURES ............................................................................ 41
CHAPTER VI TROULBESHOOTING ............................................................................... 42
CARBONATOR .................................................................................................... 42
WATER PUMP MOTOR WILL NOT OPERATE ..................................... 42
WATER PUMP MOTOR WILL NOT SHUT OFF .................................... 42
WATER PUMP WILL NOT SHUT OFF AND PRESSURE
RELIEF ENGAGED................................................................................. 42
SHORT CYCLING OF WATER PUMP MOTOR .................................... 42
WATER PUMP CAPACITY TOO LOW................................................... 42
WATER PUMP OPERATES BUT WATER PUMP DOES
NOT PUMP ............................................................................................. 42
FROZEN WATER BATH ......................................................................... 43
COOLING OR CONDENSING UNIT NOT OPERATIONAL ................... 43
AGITATOR MOTOR NOT OPERATING ................................................ 43
COMPRESSOR DOES NOT OPERATE ................................................ 43
COMPRESSOR WORKS CONTINUOUSLY BUT DOES
NOT FORM SUFFICIENT ICE BANK ..................................................... 43
COMPRESSOR WILL NOT STOP AFTER SUFFICIENT
ICE BANK IS PRODUCED ..................................................................... 44
CONDENSER FAN MOTOR NOT OPERATING ................................... 44
NO WATER BEING DISPENSED ........................................................... 44
DISPENSED PRODUCT CARBONATED TO LOW ............................... 44
DISPENSED PRODUCT MAKES FOAM AS IT LEAVES
NOZZLE .................................................................................................. 45
DISPENSED PRODUCT COMES OUT CLEAR BUT FOAMS
WHEN IT TOUCHES CUP OR GLASS .................................................. 45
CARBONATION TROUBLESHOOTING FLOW CHART #1 ............................... 46
CARBONATION TROUBLESHOOTING FLOW CHART #2 ............................... 47
CARBONATION TROUBLESHOOTING FLOW CHART #3 ............................... 48
NOTE SECTION ............................................................................................................... 49
WARRANTY BOND………………………………………………………………………………50