1. Select a counter location for your draft tower and an undercounter or remote
location for your CR-UC# unit (unit requires a minimum of 6” on all side and
top). Place the CR-UC# unit as close as possible to water filter connection &
120-volt electrical outlet.
2. Place the condenser coil facing out for best air in to unit. Allow for air flow
out of cabinet as well (louver paneling if enclosed). Without adequate air flow
the unit will not operate properly.
3. Mount the draft tower and drain pan. Plumb drain line from pan to the floor
sink. Use silicone on bottom and edges of drain pan for best seal.
4. Measure and Route the insulated trunk line that is pre-plumbed from the CR-
UC# unit to the location of the draft tower.
5. Using the supplied John Guest Union fitting and Tube-to-barb fitting, connect
the braided lines, labeled “soda” and “water” to the stainless steel lines on
the draft tower, marked “1” and “2”. Line “1” goes to sparkling water
(“soda”), line “2” goes to still water (“water”).
6. Splice together the ends of the two clear (or red) re-circ tubes in the trunk at
the connection point of the tower. Use the 3/8” “U” barb fitting (in CR-Kit-
UC) to create the continual loop from the unit through the lines and back.
7. Connect water inlet line from the CR-UC# unit to your water filter system.
When using the Everpure Filter system, you’ll need to reduce down from the
¾” fpt inlet and outlet to accommodate your line size. Water line from the
CR-UC# is a 3/8” braided hose with a 3/8” barb fitting. Labeled “water”.
8. If using a Back Flow Preventer and or Water Pressure Regulator plumb in
after the water filter system. Use Water Pressure Regulator when incoming
water pressure is above 70 PSI.
9. Connect a High Pressure CO2 regulator (CR-3741) to CO2 cylinder, then
connect CO2 line from unit to regulator. CO2 braided line has a stainless
steel nut on it and is labeled “co2”.