5.2.2 Flush
In case the front panel is made of non-magnetic material, the NFC Reader can be mounted
flush (or partly protruding). Both variants requires custom mounting parts (e.g. a bracket
or similar), to assure a robust installation.
Figure 9 – Flush
5.2.2.1 Cut-out
The cut-out dimensions are determined by the exact mounting position, and should be
calculated on a case-by-case basis.
5.2.2.2 Gasket
A dedicated gasket must be used, matching the exact mounting position, to obtain a
watertight (IP65) installation and avoid water in the internal parts of the NFC Reader and
the target equipment.
5.2.3 Internal
In case the front panel is made of non-magnetic material, the NFC Reader can be mounted
internally in the target equipment – right behind the front panel – using custom mounting
parts (e.g. a bracket or similar).
Figure 10 – Internal