Datasheet

HA / HD48 Series
• Ratings from 12A to 125A @ 48-530 VAC
SCR output for heavy industrial loads
• AC or DC control
Zero-crossing (resistive loads) or random-fire (inductive loads) output
PRODUCT SELECTION
Control Voltage 12A 25A 50A 75A 90A 110A 125A
3-32 VDC HD4812 HD4825 HD4850 HD4875 HD4890 HD48110 HD48125
90-280 Vrms HA4812 HA4825 HA4850 HA4875 HA4890 HA48110 HA48125
18-36 Vrms HA4812E HA4825E HA4850E HA4875E HA4890E HA48110E HA48125E
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms] 48-530 48-530 48-530 48-530 48-530 48-530 48-530
Transient Overvoltage [Vpk] 1200 1200 1200 1200 1200 1200 1200
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 10 10 10 10 10 10 10
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) 500 500 500 500 500 500 500
Maximum Load Current (3) [Arms] 12 25 50 75 90 110 125
Minimum Load Current [mArms] 40 40 40 40 40 150 150
Maximum Surge Current (16.6ms) [Apk] 140 250 625 1000 1200 1500 1750
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.7 1.7 1.7 1.7 1.7 1.7 1.7
Thermal Resistance Junction to Case (Rjc) [°C/W] 1.48 1.02 0.63 0.31 0.28 0.25 0.22
Maximum I
2
t for Fusing (8.3 msec) [A
2
sec]
81 260 1620 4150 6000 9340 12700
Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5 0.5 0.5 0.5 0.5
For Contact information visit our web
site.
www.crydom.com
©2008 Crydom, Inc.
Specifications subject to change without notice.

Summary of content (5 pages)