Datasheet
CN Series Assemblies
Questions? Call or e-mail
+1 (877)502 5500
+44 (0) 1202 606030
sales@crydom.com
sales-europe@crydom.com
Americas
Europe
6.2 mm Base Terminal Block Design
5 & 24 VDC and 120 & 240 VAC Control Input Options
24 VDC @ 3.5 A, 48 VDC @ 100 mA and 240 VAC @ 2 A Operating Voltage Rating
Factory assembled ready to use assemblies for AC and DC output
Socket clip ts all standard 35 mm DIN rails
IP67-protected fully encapsulated SSRs
Yellow LED input status indicator
UL & cUL recognized SSRs & sockets, UL 100 K cycle extended endurance tested SSRs,
CE & RoHS compliant SSRs, sockets & assemblies
AC & DC Output
DRACN Series Assemblies
OUTPUT SPECIFICATIONS FOR ALL MODELS
DRA-CN024DXX DRA-CN048DXX DRA-CN240AXX
Operating Voltage 0-24 VDC 0-48 VDC 24-280 VAC (47-63 Hz)
Maximum Load Current @ 40°C 3.5 A 100 mA 2 A
Minimum Load Current [mA] 1 1 70
Maximum Blocking Voltage 30 VDC 60 VDC 600 VAC
Maximum Surge Current 9 A (10 ms) 300 mA (10 ms) 120/115 Apk (16.6/20 ms)
Maximum I²t for fusing (8.3/10 msec) [A² sec] N.A. N.A. 260/285
Typical On-State Voltage Drop @ Rated Current [V] 0.4 1.0 1.1 (peak)
Maximum Off-State Leakage Current @ Rated Voltage [mA] 0.001 0.001 4.0
Maximum PWM [Hz] 500 500 N.A.
Switch Configuration Normally Open Normally Open Normally Open
INPUT SPECIFICATIONS FOR DRA-CN024DXX DRA-CN024D05 DRA-CN024D24 DRA-CN024D120 DRA-CN024D240
Control Voltage Range 3-12 VDC 15-30 VDC 90-140 VAC 190-250 VAC
Min. Turn-On Voltage 3.0 VDC
15 VDC 90 VAC 190 VAC
Min. Turn-Off Voltage 1.5 VDC
12 VDC 31 VAC 60 VAC
Typical Input Current [mA] 10 mA ± 10% @ 5 VDC
9 mA ± 10% @ 24 VDC 3.4 mA ± 10% @ 120 VAC 3.4 mA ± 10% @ 240 VAC
Typical Turn-On Time 120 sec
350 sec 2 ms 3 ms
Typical Turn-Off Time 100 sec 80 sec 5 ms 6 ms
INPUT SPECIFICATIONS FOR DRA-CN048DXX DRA-CN048D05 DRA-CN048D24 DRA-CN048D120 DRA-CN048D240
Control Voltage Range 3-12 VDC 16-30 VDC 100-140 VAC 190-250 VAC
Min. Turn-On Voltage
3.0 VDC 16 VDC 100 VAC 190 VAC
Min. Turn-Off Voltage
1.5 VDC 11 VDC 32 VAC 60 VAC
Typical Input Current [mA]
6 mA ± 10% @ 5 VDC 7 mA ± 10% @ 24 VDC 3.4 mA ± 10% @ 120 VAC 3.4 mA ± 10% @ 240 VAC
Typical Turn-On Time
20 sec 20 sec 1 ms 2 ms
Typical Turn-Off Time 130 sec 130 sec 5 ms 6 ms
INPUT SPECIFICATIONS FOR DRA-CN240AXX DRA-CN240A05 DRA-CN240A24 DRA-CN240A120 DRA-CN240A240
Parameters Parameters
Control Voltage Range 3-12 VDC 15-30 VDC 90-140 VAC 190-250 VAC
Min. Turn-On Voltage
3.0 VDC 15 VDC 90 VAC 190 VAC
Min. Turn-Off Voltage
2.0 VDC 10 VDC 60 VAC 175 VAC
Typical Input Current [mA]
15 mA ± 10% @ 5 VDC 7 mA ± 10% @ 24 VDC 4 mA ± 10% @ 120 VAC 3.6 mA ± 10% @ 230 VAC
Typical Turn-On Time
1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle
Typical Turn-Off Time 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle
Overvoltage Category
Degree of protection (for SSR only)
Ambient Operating Temperature Range -20 to 60°C
Dielectric Strength, Input/Output 2.5 KV
Maximum Capacitance, Input/Output 1.5 pF
Polution Degree
2
lll
Ambient Storage Temperature Range -20 to 80 °C
Housing Material UL 94 V0
IP67
GENERAL SPECIFICATIONS FOR ALL MODELS
GENERAL NOTES
All parameters at 25°C unless otherwise specified.
See derating curves for more information.
Operating frequency higher than 500 Hz will damage SSR.
Turn-on time for random turn-on version is 0.1 msec.
3.75 KV for CN048Dxx models.
(A)
(B)
(C)
(D)
(E)
(F)
CN Series SSR and DIN rail socket are sold separately or together as a DRACN Series assembly.
MECHANICAL SPECIFICATIONS FOR ALL MODELS
Dimensions (W x H x D) 6.1 mm x 93 mm x 80 mm
31 grs (0.067 lb)Weight (Typical)
Max. Torque Output
Terminals 10 mm
5 - 7 in lb (0.56 - 0.8 Nm)
Max. Wire size Output AWG #24-14 Solid. AWG #24-14 Stranded
(A)
(B)
(C)
(D)
(D)
(D)
(F)
(E)