Datasheet

Rev. 060216
GENERAL NOTES
(1) Control voltage 18-52 VAC/VDC is available upon request.
(2) All parameters at 25°C unless otherwise specified.
(3) Output will self trigger between 900-1200 Vpk, not suitable for capacitive loads.
(4) High inductive loads requires nominal control voltage; AC input models only.
(5) Increase minimum voltage by 1 V for operations from -20 to -40°C.
(6) For ambient temperatures above 40°C the maximum control voltage must not exceed 250 VAC/VDC.
(7) Turn-on time for Instantaneous turn-on versions is 0.1 msec.
(8) AC input models operating range is -20 to 60 °C.
(9) When protected with the appropriate class and rated fuse. For detailed info please contact Crydom Technical Support.
(10) Input torque only for contactor (V,W) with screw terminals Connector.
(11) For single surge pulse Tc=25°C; Tj=125°C. For AC Output SSRs, AC RMS value of surge current equals the peak value divided by √2 (1.414).
(12) Minimum spacing to obtain max. current is 22.5mm between adjacent units.
(13) For 35 Amp Relay (”U”) layout models, use Pin Terminals (L 0.410 in x Ø 0.102 in) to install 8 AWG wire.
(14) Applicable to Relay (”U”) option.
Datasheet
DIN Rail Mount