Datasheet

MECHANICAL SPECIFICATIONS
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
2.85
[72.3]
1.88
[47.8]
0.89
[22.5]
3.62
[91.9]
1.19
[30.2]
1.87
[47.5]
4.59
[116.5]
3.54
[90]
2/T1
1/L1
+3/A1 -4/A2
Contactor Configuration
Relay Configuration
INPUT
+3/A1 -4/A2
OUTPUT
1/L1 2/T1
0.39
[9.9]
1.88
[47.8]
3.67
[93.2]
3.00
[76.2]
0.89
[22.5]
1.19
[30.2]
4.59
[116.5]
3.54
[90]
Screw
Terminal
Input Connector
Spring
Terminal
TABLE 1. Compatible Terminals
Fork Lug Ring Lug Copper Lug Copper Lug
Width [W] in (mm)
Terminals
Stud Size Dia [D] (in)
Wire Size AWG
Crydom Part No.
0.45 (11.4)
#8 (0.168)
0.45 (11.4)
#8 (0.168)
TRM0
6-0
TRM6
14-6
W D
W D
Elevator Screw (Suffix ‘W’)
The Elevator Screw option allows the screw and
clamp to be raised out of the mating threads
completely. This provides for the insertion and
use of a ring or lug type wire terminal. Refer to
TABLE 1 for Compatible Terminals.
Datasheet
DIN Rail Mount
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Protective Earth Connection
Protective Earth (PE) screw type recommended is
10-32 UNC standard not provided with SSR. Through
the use of a DIN rail ground (protective conductor)
terminal block, the DIN rail itself can be used as the
grounding bus bar. In this case, the zinc plated steel
material used for the DIN rail clip of DR22 models,
permits a secure path to ground and avoid the need of
a further PE connection.
10-32