Datasheet
DataSheet
Panel Mount
THERMAL DERATE INFORMATION
(i) SSR metal base plate acting as heat sink, it must be exposed to free ambient air.
Do not forget to visit us at: www.crydom.com
Copyright © 2014 Crydom Inc. Specifications subject to change without notice.
0
2
4
6
8
10
20 30 40 50 60 70 80
CWxxx10
Load Current (Amps)
Ambient Temperature (ºC)
5°C/W
No Heat Sink (i)
0
5
10
15
20
25
20
30 40 50 60 70 80
CWxxx25
Load Current (Amps)
Ambient Temperature (ºC)
2°C/W
3°C/W
5°C/W
0
15
30
45
60
75
90
20
30 40 50 60 70 80
Load Current (Amps)
Ambient Temperature (ºC)
CWxxx90
0.5°C/W
0.7°C/W
1°C/W
1.5°C/W
0
10
20
30
40
50
20
30 40 50 60 70 80
Load Current (Amps)
Ambient Temperature (ºC)
CWxxx50
1°C/W
1.5°C/W
2°C/W
80
100
120
60
40
20
20 30 40 50 60 70 80
0
Ambient Temperature (ºC)
Load Current (Amps)
CWxxx125
0.36°C/W
0.5°C/W
0.7°C/W
1°C/W