User Manual
INSTALLATION & OPERATION MANUAL 10080 REV 0 (03/21)
PAGE
16
OF 20
ELECTRIC COUNTER CONVECTION STEAMERMAINTENANCE
MAINTENANCE
COLD WATER CONDENSER
The steamer is equipped with a cold water condenser in the rear of the cooking chamber which helps to condense the
steam prior to discharge into the drain. The steamer freely vents itself by the negative pressure created by the condensate
water drainage. This negative pressure prevents steam leakage around the door gasket and helps draw the steam
through the cooking compartment. Steam leakage at the door may indicate a plugged or improperly installed drain.
REMOVAL OF SCALE DEPOSITS
It is recommended that your steamer be delimed once a month, or more often if necessary.
Should your steamer develop a heavy buildup of lime scale deposits, use CLR.
Before beginning deliming procedures, ensure that water is not overowing into the cooking compartment.
The generator tank has a removable sealed tank cover. The main purpose of the removable cover is for inspection of
the interior of the tank for lime build up and easy removal of large pieces of lime that will not ush out drain. Should the
tank cover have to be removed, check condition of sealing gasket before replacing cover. The hold down bolts are to be
tightened to 160 inch pound torque each.
WARNING
Disconnect the power supply to the appliance before cleaning or servicing.
CAUTION
Live steam and accumulated hot water in the compartment may be released when the door is opened.
CAUTION
The appliance and its parts are hot. Use care when operating, cleaning and servicing the appliance.
NOTICE
Contact the factory, the factory representative or local service company to perform maintenance and repairs.