Specifications

INSTALLED SOUND
• 5
C
rown’s CTs Series amplifiers provide exceptional performance, flexibility
and value for installed sound applications. CTs Series amplifiers feature
independent selection of high and low impedance operation for a specific
channel, plus power levels and features that were carefully chosen to match
the requirements of fixed install design. Easy integration with HiQNet and
CobraNet™ allows CTs amplifiers to deliver a comprehensive lineup of mon-
itoring and control features along with digital audio transport for an award-
winning digital audio solution.
`SPECIFICATIONS
Performance
Frequency Response (at 1 watt) 20 Hz to 20 kHz:
±0.25 dB.
Signal-to-Noise Ratio, A-weighted, below rated
power (20 Hz to 20 kHz): < 105 dB.
Total Harmonic Distortion (THD) at full rated
power, from 20 Hz to 20 kHz
CTs 600 & CTs 1200: < 0.1%.
CTs 2000 & CTs 3000: < 0.35%.
Intermodulation Distortion (IMD) 60 Hz and 7 kHz
at 4:1, from –40 dB to full power: < 0.1% for CTs
600/1200 and < 0.35% for CTs 2000/3000.
Damping Factor, 10 Hz to 100 Hz: > 3000.
Crosstalk (below rated power, 20 Hz to 1 kHz):
> 80 dB.
Voltage Gain (at maximum level setting)
8/4-ohm operation, 1.4V sensitivity
CTs 600: 35:1 (31 dB).
CTs 1200: 50:1 (34 dB).
CTs 2000: 63.9:1 (36 dB).
CTs 3000: 71.4:1 (37 dB).
26 dB: 20:1 (26 dB).
70V operation, 1.4V sensitivity (all models) and
100V operation, 2.0V sensitivity (CTs 2000 & CTs
3000): 50:1 (34 dB).
Common Mode Rejection (CMR) (20 Hz to 1 kHz,
typical): 50 dB.
Maximum Input Level: + 20 dBu before input
compression, +32 dBu absolute maximum.
Power
Load Impedance (Safe with all types of loads),
CTs 600 & CTs 1200: Stereo, 2 to 16 ohms and
70V; Mono, 4 to 16 ohms and 140V.
CTs 2000 & CTs 3000: Stereo, 2 to 16 ohms, 70V
and 100V; Mono, 4 to 16 ohms, 140V and 200V.
AC Line Voltages Available (+15%, –25%):
120VAC, 60 Hz and 230VAC, 50 Hz.
Power Draw at Idle (120VAC mains).
CTs 600 & CTs 1200: 24W (standby mode).
CTs 2000 & CTs 3000: 35W (standby mode).
Controls and Indicators
Front Panel Indicators: Bridge Mode, Ready,
Signal, Clip, Thermal, Fault, Data, Power.
Back Panel Controls and Connectors. Power
Cord Connector: IEC
Reset Switch: Resets the power circuit breaker.
Channel Level Controls: 21-position detented,
one per channel.
Level Attenuation: Approx. –95 dB to 0 dB gain.
High-Pass Filter: One three-position switch per
channel selects between OFF, 35 Hz and 70 Hz
3rd-order filters.
Mode Switch: Two-position switch is used to
select the amplifier’s mode of operation: Dual or
Bridge-Mono.
“Y” Input Swtich: When set to ON, this switch
parallels the input signals of the two channels, for
use when the input signal is mono. Also can be
used to daisy-chain the signal to another amplifier.
Input/Output
Input Connectors: Balanced 3-pin terminal block
connectors, one per channel, on the standard
PIP2™-BBY module.
Input Impedance: (nominally balanced, nominally
unbalanced): 10 k ohms, 5 k ohms.
Output Connectors: One four-pole touch-proof ter-
minal strip. Accepts up to 10 AWG terminal forks.
DC Output Offset (shorted input): < 2 millivolts.
Protection
CTs Series amplifiers provide extensive protection
and diagnostic capabilities, including Thermal Level
Control (TLC), fault, low-pass filters, high-pass fil-
ters, AC under/over voltage protection, DC output
servo, circuit breaker, inrush limiting, and Junction
Temperature Simulation (JTS) in CTs 600/1200.
Construction
Ventilation: Front-to-rear forced airflow. Two
continuously variable speed fans direct the airflow
through the amplifier for cooling.
Dimensions: EIA Standard 19-inch (48.3-cm)
rack mount width (EIA RS-310-B), 3.5-inch
(8.9-cm) height and 14.25-inch (36.2-cm)
depth behind the mounting surface.
Weight
Net Weight,
CTs 600: 22.8 lbs. (10.3 kg);
CTs 1200: 23.4 lbs. (10.6 kg);
CTs 2000: 27.0 lbs. (12.2 kg);
CTs 3000: 27.7 lbs. (12.6 kg).
Shipping Weight,
CTs 600: 27.7 lbs. (12.6 kg);
CTs 1200: 28.3 lbs. (12.8 kg);
CTs 2000: 32.0 lbs. (14.5 kg);
CTs 3000: 32.7 lbs. (14.8 kg).
System Solutions
IQ
®
PIP™ LITE, IQ-PIP USP3,
IQ-PIP USP3/CN, PIP-3632,
PIP-4622, PIP-4632 and PIP-USL.
Accessories
T-170V: This is an autoformer that allows 100V
output from the CTs 8200, and allows other
amplifiers without direct constant voltage output
to be easily integrated into distributed systems.
TP-170V: This is a rack-mountable panel with
four autoformers as described above.
Regulatory Certifications
Other Applications
Note: Specifications apply to units in Dual mode with 8-
ohm loads and rated input sensitivity unless otherwise