Specifications
International Radio and Electronics Corporation
25166 Leer Drive Elkhart, Indiana 46514 • 574–262–8900 • www.irec1.com
3
-
7
[FWD Pwr Tweak] Adjust forward power reading to correspond to a reading on a
calibrated wattmeter. Adjustment range is 90 - 110 %.
[REV Pwr Tweak] Adjust reverse power reading to correspond to a reading on a
calibrated wattmeter. Adjustment range is 90 - 110 %.
[CPU Reset] Used to test the ability for the CPU to reset.
[ABC Override] Use to set RF power level for initial power up. Default setting is 80%
of rated power of unit.
[Back] Returns to the previous menu.
[Secondary]
[Date/Time] Settings for the real-time clock.
[New Password] Change the Settings password.
[Omnia Board] Use this menu to access the Crown/Omnia DP3 processor functions. See
section 3.11.
[FSK] Use this menu to enter the FSK code for the translator.
[RMS Board] Selects between ON/OFF for the RMS option.
[RMS Menu] Enter phone numbers that the RMS will call in the event of a failure.
[Factory Reset] Returns user settings to factory settings.
[Back] Returns to previous menu.
3.7 Factory Setting Functions
Factory settings are programmed by the manufacturer and are provided only to authorized
personnel.