Instruction manual

page 9
CT Power Amplifiers
Operation Manual
6 Front Panel
1. Fault Indicator
Red LED
One per output channel
Flashes when the amplier output channel
has stopped operating. Usually this means
that the amplifier must be serviced. (See
Section 15 Troubleshooting)
2. Thermal Indicator
Red LED
One per output channel
If exceeds Thermal Limits, output channels
will shut down in pairs until thermal levels
are within tolerant ranges.
Illuminates when the channel approaches
temperature constraints or is about to shut
down. Audible distortion may be heard.
Unit stops amplication for each channel
until temperature returns to acceptable level.
Once the amp cools off enough, led turns
off, audio starts again.
3. Clip Indicator
Red LED
One per output channel
Illuminates when the channel is at the
threshold of audible distortion (See
Section 15 Troubleshooting – reduce
input level)
When the limiter is turned on the Clip
Indicator will illuminate when the
limiter is protecting the amplifier from
input overload.
4. Signal Indicator
Green LED
One per input channel
Illuminates when the input signal
exceeds -24dBu
5. Ready Indicator
Green LED
One per input channel
Illuminates when the channel is ready
for signal
Illuminates when the channel is
initialized and ready to produce audio
output.
Ready indicator will ash when the
channel is in standby.
Ready Indictor will not illuminate or
flash when the amplifier is in deep sleep.
6. Power Indicator
Blue LED
Indicates AC power has been applied
and is within the safe operating range of
the power supply. The LED will flash
when the AC line voltage is above or
below the nominal rated value. The LED
will also flash when the amplifier is in
Deep Sleep mode AND the power button
has been pushed.
7. Data Indicator
Yellow LED (not functional in
analog version)
Indicates network activity
Reserved for future releases
(Lite and DSP)
8. Power Button
On/off push button
9. Cooling Vent
Allows for air ow and cooling
of the amplifier
12 3456789