Specifications

1
WaterMax
SUPER SPORTS TURF PUMP STATION
Variable Frequency Drive Control System
GENERAL SPECIFICATIONS
Project Name: ?
Project Location: ?
Pumping System Model #: WaterMax SSTV-HP-Voltage-Phase-Flow-Boost
Total Design Criteria: Quantity of Pumps: ?
Station Design Capacity: ? GPM @ ? PSI Discharge
08/22/06
SCOPE OF WORK
It is the intention of this specification to describe an automatic, prefabricated, self-enclosed, pump station for
irrigation purposes. Design, fabrication, testing and service shall be the sole responsibility of the pump station
manufacturer. The pump station shall provide water to the irrigation system while simultaneously maintaining
a constant discharge pressure by using a prefabricated pump station with variable frequency drive (VFD)
pumps for pressure regulation, under varying flow conditions up to the maximum specified capacity.
Construction shall include a fabricated steel plate and skid assembly to support all components during
shipping and to serve as the installed mounting base.
SECTION 1: GENERAL
1.1 The prefabricated pumping station shall have a minimum capacity and discharge pressure at skid
edge as stated in the technical specifications.
1.2 The station shall be completely wired, piped, hydraulically and electrically tested prior shipment.
1.3 The discharge manifold from the pump station shall terminate at or near the pump station skid edge
and be provided by the pump station manufacturer.
The pumping station shall be model number WaterMax SST as manufactured by WATERTRONICS, INC. 525
Industrial Drive, P.O. Box 530, Hartland, Wisconsin 53029-0530, www.watertronics.com
.
SECTION 2: MANUFACTURER REQUIREMENTS
2.1 MANUFACTURER
The pump station shall be manufactured by Watertronics Inc., Hartland, Wisconsin. The following information
must be furnished by the contractor or manufacturers representative:
a. A complete specification and submittal of all major components for the proposed pump
station with individual pump performance verification.
b. A detailed pump station proposal drawing complete with component location, sizes and
dimensions specific to the installation.
c. A complete electrical schematic for all high and low voltage circuits showing breaker/fuse
sizing, wire numbering and color.
d. Pump station manufacturers U.L. file number for the entire pump station.
e. A copy of the manufacturers certificate of insurance.