Mega-Stor Indirect Fired Water Heater Installation Manual

10
V. BEFORE STARTING INSTALLATION
Characteristic Min Max
pH 6.0 8.0
Chloride (PPM) 0.0 80.0
TABLE 5.1: WATER CHEMISTRY
REQUIREMENTS
Water used in the Mega-Stor must have characteristics falling
within the following limits:
1) Be sure that the planned installation is in accordance with all local codes.
2) Be certain the domestic water supply to the tank has physical and chemical characteristics that fall within the limits shown

consulted.
3) Read and understand all installation requirements in this manual.
IMPORTANT
Water with characteristics outside the limits shown in
Table 5.1 may severely shorten the life of the tank due to
corrosion. Damage to tanks in such cases is not covered
under warranty.
VI. LOCATING THE MEGA-STOR

capable of supporting it.
WARNING
Failure to properly support an MS tank could result in property damage or personal injury.
2) Locate the Mega-Stor in a location where a leak in the tank, the adjacent piping, or an open T&P valve will not damage the
surrounding structure. If the area around the desired tank location is highly susceptible to water damage, install the Mega-
Stor in a pan with a drain.

called for in Table 2.1 through the coil. Also, the further the Mega-Stor is from the boiler, the longer the response of the
boiler will be to a call from the Mega-Stor zone. If long runs exist between the boiler and Mega-Stor it is advisable to
insulate the piping.