Specifications

CS-47 GSM Link - Configuration Guide Chapter 5 - Configuring the CS-47 Link Unit
11
Configuring the Unit Remotely
ThissectiondescribeshowtouseyourPCorlaptoptoconfiguretheunitremotely
usinganotherCS47linkmodem.
IMPORTANT NOTES
Before you are able to configure the system unit remotely it must be
first configured locally.
Pre-requisites
TheremoteCS47linkmodemmustbeastandaloneunitandNOTbeconnectedto
aRunnerkeypadbus.
Youneedthephonenumberandpasswordoftheremotesystemyouwantto
contactandconfigure.
MakesurethatbothUnitsregisteredtoNetwork.
Remote Site Configuration Setup
Figure 1: Remote Configuration Setup