Specifications

CS-47 GSM Link - Configuration Guide Chapter 4 - Installing the Hardware Unit
8
CHAPTER 4.
Installing the Hardware Unit
IMPORTANT NOTES
If the GSM unit is being installed as a backup module, it should
NOT be installed too close to the panel.
It is recommended to configure the unit at the lab before
installing it at the customer’s premises.
To install the hardware unit containing the CS-47 GSM link:
1. Chooseasuitablelocationwithinthesecuredareafortheunitwithin1to20
metersfromtheRunner.
2. Usingthepapertemplatedrill4holesinthewalltomounttheunit.
3. Usingfourscrewsandrawlplugs(wallplugs),fixtheunittothe
wallorany
otherfirmflatsurface.
4. PowerOFFtheRunneranddisconnectthebackupbattery.
5. ConnecttheunittotheRunnerbus.
Thebusconsistsoffourwires:Pos(+12V),Neg(12V),ClkandData.
SeePage6
6. IftheCS47linkis
goingtouseanexternal12VpowersupplytheGNDwire
fromthepowersupplyMUSTbeconnectedtotheGNDBus(Neg)terminal.
7. InserttheSIMcard intotheSIMcardholder.
Ifyouhaven’tcancelledcallwaitingandallroamingoptionsitisrecommended
todoso
bycontactingyourISP(InternetServiceProvider).
8. Ensurethattheantennaisproperlyconnected.
9. PowerONtheRunner.
10. Connectthebackupbattery.