Specifications
CS-47 GSM Link - Configuration Guide Chapter 3 - Physical Layout
7
Table 1: Component Description
Component Description
Status LEDs
NET: Turns green when there is communication with the
TCP/IP server.
BUS: Blinks yellow when the bus is communicationg with
the control panel.
FAIL: Blinks or solid red on network error. For example, a
problem with the SIM card or GSM network , open tamper
Power LED Turns red when power is applied to the unit.
Modem LED Blinks yellow when the GSM service is connected.
SIM Card Holder SIM card used for the GSM modem.
Antenna Cellular phone antenna connector.
Tamper Switch Activates alarm if cover is removed.
Program
Connector
Connector for connecting the inputs and outputs.
CONFIG PORT Serial port that connects to a PC or laptop.
Battery
Connector
Backup rechargeable battery 12 V/1.3 Ah lead acid.
Bus Connector For communication with the control panel.
Power LED Red when power good.
GSM Modem Siemens TC63 based GSM modem
GSM Service LED Blinks yellow when GSM service is connected.
Output 1&2
Gnd
Terminal Block
Input 1&2