Datasheet
Immunity to radio frequency in common mode acc. to
IEC/EN 61000
-4-6
Level III (10V rms : 0.15 M Hz to 80 M Hz)
Immunity to voltage dips and breaks acc. to IEC/EN 61000
-
4-11
0 % residual voltage, 1 cycle
70 % residual voltage, 25/30 cycles
Mains
-
borne and radiated emissions acc. to EN 55022
(CISPR22), EN55011 (CISPR11)
Class B
Fixing : Symmetrical DIN rail
35 mm
Terminal capacity Single
-wire without ferrule
1x0,5→3,3mm
2
(AWG20→AWG12)
2x0,5→2,5mm
2
(AWG20→AWG14)
Terminal capacity Multi
-wire with ferrule
1x0,5→2,5mm
2
(AWG20→AWG14)
2x0,5→1,5mm
2
(AWG20→AWG16)
Housing material
Self-extinguishing
Shock test IEC/EN 60068
-2-27
15 g -
11 ms
Short interruption on power line acc to IEC/EN 61000
-4-11
0 % residual voltage, 250/300 cycles
Timing
Minimum pulse duration typically
30 ms
Minimum pulse duration typically (under load)
100 ms
Maximum reset time by de
-energisation typically
120 ms
Supply
Operating range
85→110%Un
Max. absorbed power
15 VA (400 VAC)
50 VA (240 VAC)
0,7 W (24 VDC)
1,2 VA (12 VAC)
0,5 W (12 VDC)
Output specification
2 changeover relays, AgNi (cadmium-free)
2 C/O
RQR1
-
RQR6 2 open contacts
General characteristics
Weight : casing 22,5 mm
88 866 175 (RQR1) : 81 g
88 866 176 (RQR6) : 81 g
88 866 215 (RA2R1) : 87 g
88 866 300 (RU2R4) : 86 g
88 866 303 (RU2R3) : 90 g
88 866 305 (RU2R1) : 88 g
88 866 385 (RX2R1) : 88 g
Insulation resistance according to IEC/EN 60664
-1
> 500 M
Ω
(
500 VDC)
Dimensions (mm)
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
12/02/2015 www.crouzet.com