Data Sheet
Page 15 of 14
Programming Mode
Programming Main Menu
#
Parameter
Value
1
Pass
If "Lock" function is on, pass needs to be entered
0000
2
Basic Prog
Enter to Basic Programming Mode
3
Advanced Prog
Enter to Advanced Programming Mode
4
Test
Enter to Test Mode
Basic Prog Menu
#
Parameter
Value
1
Function
Select the timing function
A Ab
H Ht
Ac Ad
L Li D Di
AMt
T
W
At
B
C
2
Time Range
Select the timing range
-.---s
---.-m
--.--s
----m
---.-s
--h--m
----s
---.-h
--m--s
----h
3
Count
Select the timing count up or down
Up
Down
4
Memory
Activate memory option (save timing after power off)
Off
On
5
Output 2
Select if Out 2 works timed or instantaneous (MDA2, GDS2)
Timed
Instantaneous
Advanced Prog Menu
#
Parameter
Value
1
Input Type
Select input to work with a NPN or PNP signal
PNP NPN
2
Time Change
Select if a timing change will be applied during current cycle
(Now) or at the end of it (End)
Now End
3
Time Limit
Select upper time limit
9999 0000