Datasheet

Standards Specifications
Description
MDE1…24U
MDE1…MVA
GDF1
MDF1
MDA2
GDS2
CEE Directive
2014/30/EU: EMC,
2014/35/EU: Low voltage
Approvals / Marking
CE, cULus Listed Industrial Control Equipment
Security standard
IEC 60664-1: Insulation coordination for equipment within low-voltage systems
Conformity with environmental directives
2015/863/UE: RoHS
1907/2006: Reach
2012/19/UE: WEEE
Product standard
IEC 61812-1: Specified time relays for industrial use
UL 508 (60947-4-1): Industrial Control Equipment (NRNT- Industrial Control Switches)
Immunity to electrostatic discharges
Level III Air +/-8 KV / Contact +/-6 KV
Immunity to radiated, radio-frequency,
electromagnetic field
IEC61000-4-3: Level III, 10V/m (80 MHz to 1 GHz) 80% AM (1 kHz), 3 V/m (1,4 to 2 GHz)
80% AM (1KHz), 1 V/m (2 to 2.7 GHz) 80% AM (1KHz)
Immunity to rapid transient bursts
IEC 61000-4-4: Level IV, direct +/-4kV (power supply) / capacitive coupling clamp +/-2 KV,
(command input and outputs)
Immunity to shock waves on power supply
IEC 61000-4-5: Level III, line-to-earth +/-2kV / line-to-line +/-1kV
Immunity to radiofrequency in common
mode
IEC 61000-4-6: Level III, 10Vrms (0,15 to 80 MHz) 80% AM (1 kHz)
Immunity to voltage dips and breaks
IEC 61000-4-11:
Industrial Class II, 0 % residual voltage during 1 cycle a.c.power ports, 70 % residual voltage
during 25/30 cycles a.c. power ports, 0 % residual voltage, 250/300 cycles a.c. power ports.
Residential: 0 % residual voltage during 10 cycle a.c.power ports, 40 % residual voltage
during 10 cycles a.c. power ports, 70 % residual voltage during 10 cycles a.c. power ports, 0
% residual voltage, 250/300 cycles a.c. power ports
AC/DC main port emissions
EN55022 / CISPR22 Class B
EN 55011 / CISPR11 Class B, Group 1
Radiated emissions
EN55022 / CISPR22 Class B
EN 55011 / CISPR11 Class B, Group 1
| 01/
2018| DIGITAL TIMER
| 4