Datasheet
3 11/2019 | Universal Digital Timer CONTROL.CROUZET.COM
DZ1R08MV1
OperatingtemperatureIEC60068-2 -20→+50°C
StoragetemperatureIEC60068-2 -40°C→30°CMax(foroptimalstoragetime)
HumidityIEC60068-2-30 93%withoutcondensation
VibrationresistanceIEC60068-2-6 ±0.15mmfrom10Hz→60Hz
2gfrom60Hz→150Hz
ShockresistanceIEC60068-2-27 15gn-11ms;3x6axis(Outputnon-energized)
5gn-11ms;3x6axis(Outputenergized)
DroptoconcreteoorIEC60068-2-32 High:0.75m
Weight 81g
100gwithpackaging
StandardsSpecications
CEE Directive:
2014/30/EU
2014/35/EU
EMC
Low voltage
Approvals/Marking CE
cULus Listed Industrial Control Equipment
SecuritystandardIEC60664-1 Insulation coordination for equipment within low-voltage systems
Conformity with environmental directives
2015/863/UE
1907/2006
2012/19/UE
2006/66/CE
RoHS
Reach
WEEE
Battery Directive
ProductstandardIEC61812-1
UL60947-4-1
Speciedtimerelaysforindustrialuse
Industrial Control Equipment (NRNT- Industrial Control Switches)
Electromagnetic compatibility
IEC61000-6-2
IEC61000-6-3
IEC61000-6-4
Immunity for industrial environment
Emission residential environment
Emission industrial environment
ImmunitytoelectrostaticdischargesIEC61000-4-2 LevelIIIAir±8KV/Contact±6KV
Immunitytoradiated,radio-frequency,electromagneticeld
IEC61000-4-3
Level III
10V/m(80MHz→1GHz)80%AM(1kHz)
3V/m(1.4→2GHz)80%AM(1KHz)
1V/m(2→2.7GHz)80%AM(1KHz)
ImmunitytorapidtransientburstsIEC61000-4-4 Level III
direct±2kV(powersupply)
capacitivecouplingclamp±1KV(commandinputandoutputs)
ImmunitytoshockwavesonpowersupplyIEC61000-4-5 Level III
line-to-earth±2kV
line-to-line±1kV
ImmunitytoradiofrequencyincommonmodeIEC61000-4-6 Level III
10Vrms(0.15→80MHz)80%AM(1kHz)
ImmunitytovoltagedipsandbreaksIEC61000-4-11 0%residualvoltage/1cycle(Crit.B),
40%residualvoltage/10cycles50Hz/12cycles60Hz(CritC)
70%residualvoltage/25cycles50Hz/30cycles60Hz(CritC)
Short interruptions: