Instructions / Assembly

Pre Operational Instructions
The following items should be checked before attempting to operate the dryer:
Read all “IMPORTANT” AND “WARNING” labels attached to the dryer.
Check incoming supply voltage to be sure that it is the same as indicated on the data label.
GAS MODELS – Check to ensure that the dryer is connected to the type of gas indicated on
the dryer data label.
GAS MODELS – Be sure that all gas shutoff valves are in the open position.
Be sure all back panels (guards) and electric box covers are in place.
Be sure the service doors are closed and securely in place.
Be sure the lint lter is securely in place.
Rotate the tumbler (drum) by hand in both directions to be sure it moves freely.
Check bolts, nuts, screws, terminals, and ttings for tightness and security.
Check that the vent is connected to the dryer and is exhausted to the outdoors.
Function Checks
All dryers are thoroughly tested and inspected before leaving the factory. However, a test should be
performed before the dryer is publicly used. It is possible that adjustments have changed in transit
or due to marginal location (installation) conditions.
Gas Dryers
Open all shutoff valves.
Turn on electric power to the dryer.
Run the “No Heat” drying program and check if the drum is rotating properly.
Run the “Low Heat” and to check the Ignition.
Refer to the Operating Instructions for starting your particular model dryer.
When a gas dryer is rst started (during initial start-up), it has a tendency not to ignite on the rst
ignition attempt. This is because the gas supply piping is lled with air, so it may take a few minutes
for the air to be purged from the lines.
NOTE
During the purging period, check to be sure that all gas shutoff valves are open.
A gas pressure test should be taken at the gas valve pressure tap of each dryer to ensure that
the water column pressure is correct and consistent.
Water column pressure requirements (measured at the pressure tap of the gas valve body)
must be veried.
Dryers congured for L.P. operation do not have a regulator. The water column pressure must
be regulated at the source (L.P. tank), or an external regulator must be added to each dryers
L.P. connection line.