Instructions / Assembly
Installation
2:9
WARNING
• Fire or explosion could result due to failure to isolate or disconnect the gas supply as noted.
The dryer must be connected to the type of heat/gas indicated on the data label and the correct
pressure must be conrmed. If this is not possible, do not connect the dryer. Contact the reseller
who sold the dryer or the manufacturer.
Heat Input / Gas Consumption/Orice (Injector) Data
Consistent gas pressure is essential at all dryer gas connections. It is recommended that a 3/4-
inch (19mm) pipe gas loop be installed in the supply line servicing a bank of dryers. For natural
gas installation an in-line pressure regulator must be installed in the gas supply line if the gas
pressure exceeds 10.0 in WC (25 mb) pressure.
A plugged tap, accessible for a pressure gauge connection, must be installed in the main gas
supply line immediately upstream of the dryers.
NG
LPG
IGNITOR
GAS NOZZLE
GAS VALVE
GAS PIPE
GAS SHUTOFF VALVE
GAS VALVE BRACKET
GAS VALVE ASSEMBLY BASE
BURNER
IGNITOR BRACKET
Gas Type
Nominal
Heating
Value
Supply
Pressure
Gross Heat
Input
Orice
Size
Orice
Injector
Quantity
Burner
Pressure
Btu/ft
3
In-WC Btu/hr kW DMS mm In-WC
Natural Gas 1000 4.5 - 10.5 19000 5.5 44 2.2 1 3
Liquid Propane 2500 11 - 14 19000 5.5 55 1.3 1 10.5