Instructions / Assembly

Installation
2:2
Dryer Enclosure Requirements
Commercial
Bulkheads and partitions are recommended to be made of noncombustible material.
The requirement to allow the door to open completely is 36 inches (91 cm).
A minimum overhead clearance of 6-inches (15.24 cm) is recommended.
Dryer should be positioned a minimum of 12-inches (30.5 cm) away from the nearest
obstruction. 24-inches (61 cm) is recommended for ease of installation, maintenance, and
service.
Flooring should be level and below dryer cabinet for ease of removing panels during
maintenance.
Dryers may be positioned side by side.
IMPORTANT
The Dryer – Dryer stacked unit is recommended to be installed by 2 people.
For stacked washer and dryer unit, the washer should be installed in accordance with washer
installation manual and tested rst.
Minimum clearances for closet and alcove installations: Sides 1", Rear 3", Top 1",
Front 3". Closet doors must be louvered or otherwise ventilated and have at least
60 square inches of open area.
WARNING