Owners Manual

24 American Dryer Corp. 112146-61
Summary: LO Temp is programmable from a minimum of 100 ° F to a maximum of 190 ° F in ten-degree increment s or from a
minimum of 38° C to a maximum of 88° C in five-degree increments.
Program Location 05 (PL05)
LO Temp
Location to be viewed/changed.
Press Perm Press key.
Display will read “LO°F, LO Temp
status for 3-seconds and then the
actual temperature programmed.
If no changes, press Perm Press
key otherwise press HI or LO
key and then Perm Press key.
LO°F
Perm Press
120F HI Temp
Perm Press
LO Temp
Refer to Programming
Instructions for instructions on
entering program locations.
(Wait 3-Seconds)
Automatically goes
into PL06 Program without
PL06 Display Mode
PL05
Continued on next page
Temperature Decrease Temperature Increase
NOTICE: To eliminate potential
overheating do not set temperature
in PL03, PL05, and PL07 above
150° F (65° C)