User manual

Clearance to Side
Minimum clearance required to any combustible material to the side of the appliance must be l50mm.
Clearance to Shelves
Minimum clearance to the underside of a l50mm combustible shelf from the hearth must be 790mm, add 12.5mm
to this dimension for every 25mm increase in the depth of the shelf.
To light The Appliance
Remove the Fret (controls cover) to gain access. Press and turn the gas control knob anticlockwise until the
indicator dot is opposite the IGN. Keep the gas control knob fully depressed.
Press and release the piezo igniter until the pilot flame situated on the left-hand (see Fig 2) side of the burner has lit
at both ports. Keep the gas control depressed for a further 10 to 15 seconds.
Release the gas control and check that the pilot flame remains lit. Note: For convenience, the unit can be operated
with the pilot only, i.e. with the control knob set in the IGN position. In the event of igniter failure a match or taper
can light the pilot, place at the pilot position and depress the gas control.
Push in the gas control slightly and turn anti-clockwise so that the indicator dot is at the required setting. Replace
the fret (controls cover).
To turn off the appliance and pilot, turn the gas control clockwise from any position until the indicator dot is
opposite OFF
IMPORTANT: After turning off or if the pilot and the appliance goes out for any reason, wait for three minutes
before attempting to relight.
- 3 -