User manual

Contents Check List
Fire Box Assembly-c/w Burner Assembly Coal Pack Including;
Lower Fibre Back 11 Medium Strata Coals
L& R Hand Side Cheeks 8 Small Strata Coals
Simulated Coal front
Burner Inserts
Coal Support Shelf
Spacer Frame Assy.
Spacer frame Fixing Kit
Fitting Kit: - 7" (175mm.) & 5" (125mm.) Spigot Restrictors
Screws & rawl Plugs, Fixing Straps, and self-tap screws
3 x Lengths of Bundy pipe
Installation and Servicing Instructions
Users instructions
Fire Surround and Opening Requirements
7" Diameter Flue, Chairbrick and Builders opening (Class I). See Fig 1.
5" Diameter Flue and Metal Flue Box (Class 2). See Fig 2.
Precast Flues. See Fig 3.
Clearance to side (timber surrounds etc.)
Minimum clearance required to any combustible material to the side of the appliance must be 150mm.
Clearance to Shelves
Minimum clearance to the underside of a l50mm deep combustible shelf from the hearth must be 790mm.
Add 12.5mrn to this clearance for every 25mm increase in depth of shelf.
- 4 -
Depth A is to be a
minimum of l50mm from
the knee to the front face
of the surround to satisfy
the debris collection
requirement.
Depth B is nominally
70mm.
If no chairbrick is fitted,
the minimum d1stance
required between the rear
of the opening and the
rear of the frame is
220mm.