0102 095 50034 CLASS 1 – FLAME SYSTEM 2 USERS (Pages 2-3)/ INSTALLATION (Pages 4-8) AND SERVICING INSTRUCTIONS THIS CAT I2H APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20mbar IN GB and IE HAND THESE INSTRUCTIONS TO THE USER
86(56 ,16758&7,216 '(6&5,37,21 The Flame System 2 has a single aerated burner, the design of which produces a ribbon of flame which runs across the front of the fire bed. A single gas control combined with piezo igniter selects ignition (pilot only) and can be turned anticlockwise to select a high rate and then a reduced input at the maximum rotation. For extra safety the control is designed so that gas cannot be allowed to reach the burner until pilot ignition has been proven.
5. Depress the gas control slightly and turn anti-clockwise until the indictor mark is aligned with the letters LOW. The burner will now be at minimum rate. 6. To turn the appliance ‘off’, return the control to the ‘OFF’ position. 7. If for any reason the fire cuts out, return the control knob to the `OFF’ position and wait 3 minutes before relighting. 8.
INSTALLATION INSTRUCTIONS ,167$//$7,21 5(48,5(0(176 $1' 5(*8/$7,216 The appliance must be installed by a competent person in accordance with the current Gas Safety (Installation and Use) Regulations or the rules in force and in accordance with the manufacturer’s instructions. Failure to do so could lead to prosecution. The following are the relevant Codes of Practice and British Standards. The Building Regulations issued by the Department of the Environment.
Page 4 ,167$//,1* 7+( $33/,$1&( If a fire back (chair brick) is fitted in the existing builders opening (constructed of non-combustible material) it will be necessary to remove it together with any infill or rubble. Any remedial work should be carried out including levelling the base beneath the fire. The sizes required for the opening are shown in Fig 2.
Page 5 72 9(5,)< 7+( ,1/(7 35(6685( The inlet pressure should be observed at 20mbar +/- 1mbar when the appliance is operating at its maximum rate. Any significant reduction below an inlet pressure of 20mbar will indicate a restriction in the gas supply to the appliance that should be identified and corrected. If there are any other appliances, which are relatively high rated (e.g.
Page 6 $'9,6( 7+$7: The curing effect of heating the coals will cause an initial odour, which although not harmful, may require additional ventilation until the odour has disappeared. Any debris or soot is cleaned from the appliance. Advise the customer that they should read their Users Instructions before operating the fire and always follow the advice in the section headed ‘Removal of Debris or Soot Deposits’. The appliance must be serviced annually by a competent person; i.e.
Page 7 iii) TO REPLACE THE OXY-PILOT ASSEMBLY: including electrode and thermocouple): THE PART MUST ONLY BE THE MANUFACTURER’S SUPPLIED ITEM NO ADJUSTMENT OR ALTERATION MAY BE MADE OR THE PILOT SYSTEM OVER-RIDDEN. The two securing screws are accessed through the front of the control panel. Undo the pipe at the inlet of the pilot assembly and undo the thermocouple connection at the back of the tap. Withdraw the pilot assembly. Clean off any lint or fluff taking care to avoid damage.
*Technical Help Line 0906 8633268 *Calls charged at 50p per minute Page 8