Technical data

18” Inset Taper 010710
215mm
2.3 TECHNICAL DATA 18” Inset
Fig. 7 Fig. 8
2.4 INSTALLING THE APPLIANCE (Ventilation)
Ventilation required for this appliance must be fitted with the rules in force and checked regularly for obstructions:-
If the appliance is installed in GREAT BRITAIN, additional ventilation is required.
If the appliance is installed in IRELAND, a minimal cross sectional area of 100cm
2
is required.
Page 7
Minimum
height of
opening is
555mm
Minimum
width of
opening is
415mm
In
j
ector 044/341/196/087M
Gas Control MP 21301B
Main Burner Aeromatix AC03/211658
Thermocou
p
le T100/927-400
I
nition Sin
g
le s
p
ark electrode direct to main burner
Gas Connection 8mm OD
(
restrictor elbow
)
Gas T
yp
e G20 NATURAL GAS
Maximum Heat In
p
ut 7.8kW
(
26.003btu/hr
)
Gross
SPECIFICATIONS
Minimum Heat In
p
ut 3.6kW
(
12,283btu/hr
)
Su
pp
l
y
Settin
g
Pressure 20mbar +/- 1mbar
(
Cold
)
Flue T
yp
es Class 1
295mm
415mm
Minimum
Depth of
opening is
215mm