Technical data
18” Inset Taper 010710 
Section 3 – Maintenance & Servicing 
3.1  REMOVAL OF DEBRIS OR SOOT                 18” Inset 
Allow the appliance to cool for two to three hours before removing all of the fibre components for cleaning purposes. Once all the fibre is 
removed, check that no debris is located in the burner holes of the appliance. If any debris is located, carefully remove any foreign matter 
from the burner holes. 
Any soot deposits or debris left on the fibre components may be removed by using a soft brush. Brush with the component held away from 
your face so that you avoid inhaling the dust. CROSSLEE plc DOES
 NOT recommend the use of a normal vacuum cleaner, which may 
blow dust back into the room. 
To ensure that the release of fibres from these RCF articles is kept to a minimum, during installation and servicing, CROSSLEE 
recommend that a HEPA filtered vacuum is used to remove any dust and soot accumulated in and around the appliance before and after 
working. When replacing these articles, CROSSLEE recommend that they are NOT
 broken up, but are sealed in heavy duty polythene 
bags and clearly labelled as RCF
 WASTE. This is not classified as hazardous waste and may be disposed of at a tipping site licensed for 
the disposal of industrial waste. Protective clothing is not required when handling these articles although CROSSLEE recommend you 
follow the normal hygiene rules of not smoking, eating or drinking in the work area and to always wash your hands before doing so. 
3.2  SERVICING COMPONENTS BELOW THE BURNER 
To gain access to the components below the burner, remove the fibre components and the burner unit from the firebox. 
CLEANING OR REPLACING THE INJECTOR (Fig. 23). 
  Unscrew the compression nuts from the gas control to the injector. 
  Remove the formed pipe. 
  Unscrew the injector from the burner. 
 Replace in reverse order. 
REPLACING THE GAS CONTROL (Fig. 24). 
  Disconnect the two formed pipes from the gas control. 
  Disconnect the thermocouple from the gas control. 
  Remove the control knob. 
  Undo the retaining nut on the facia panel. 
 Replace in reverse order. 
REPLACING THE PIEZO IGNITOR (Fig.25). 
  Disconnect the HT lead from the piezo ignitor. 
  Retain the metal fixing nut with one finger and rotate piezo ignitor. 
 Replace in reverse order. 
REPLACING THE MAIN BURNER & THERMOCOUPLE (Fig.26). 
(Atmospheric sensing device) 
  Unscrew the two fastening nuts and washers from the rear of the burner unit. 
  Remove the stainless steel baffle and spacer plate. 
  Disconnect the formed pipe connecting the gas control and injector. 
  Unscrew the injector from the main burner 
  Unscrew the two fastening nuts and washers from the front of the burner unit. 
  Remove the main burner. 
  Unscrew the locknut, retaining the thermocouple. 
  Remove the thermocouple. 
 Replace in reverse order. 
Page 13 
Fig. 23 
Fig. 24 
Fig. 25 
Fig. 26 