Alarm Severity
The CrossFire System supports four different alarm levels Warning, Minor, Major, and Critical.
Use the following steps to set up the appropriate alarm severity.
1. Log in the WebOMT, and go to the Alarms section.
2. Select the appropriate severity in the drop-down box for the alarm in use.
3. Click Set to save the settings.
4. Wait 3 minutes after completing the setup, then query to see if there is an alarm.
Blank Indicator means alarm disabled;
Green color means no alarm;
Red color means the alarm is triggered.
Note: All alarms are default disabled at the factory. Disable the alarms not in use to avoid false alarms.
Note: Power Interruption Alarm and Battery Failure Alarm can NOT be enabled if there is no accumulator installed.
Figure 30. Alarm Severity Setup
Alarm Threshold
To set up the alarm threshold:
1. Log in the OMT, and go to the Alarm Thresholds section.
2. Locate the fields and set the appropriate values.
3. Click Set to save the settings.