Access to the OMT on the Slave Devices
In the CrossFire system, E2s and M2RU as well as the Slave A2s, are defined as Slaves. They have no fixed IP address. The IP
addresses are assigned by the host automatically, based on the network topology.
To set up wired access to the OMT:
1. Connect a PC to the slave device with a network cable in the CONSOLE port on the front panel.
2. Change the TCP/IP properties:
a. Enable Obtain an IP address automatically by clicking the check box.
b. Enable Obtain DNS server address automatically by clicking the check box.
3. Check the status of the Local Area Connection and confirm the connection.
4. Open a browser window and enter the default gateway in the navigation bar to access the WebOMT page. The default fixed IP
address is https://12.7.1.1 as the default gateway.
Figure 7. TCP/IP Properties Configuration – Slave devices