Installation Manual

MID POWER
4 x 37dBm Output
5G NR Compli
© Sunwave IM_CF_M2 v2.0.1 | 49 of 51
Contact
us
today:
www.sunwave.com
cf_support@sunwave.com
RU Optical Port Description
Obtain the required lengths of optical fibers for all the optical connections and connect the fibers on the front panel of Remote Unit.
The interface type of SFP transceivers is an LC connector.
It is important to label all ports on the fiber distribution panel correctly.
It is recommended to include additional length/slack in the optical fiber to allow future re-configurations without requiring
additional splices.
RU Front Panel Interfaces
SN
Interface Name
Description
1
CH4
PA 2 Module Interface, 4.3-10 female Connector
2
CH3
PA 2 Module Interface, 4.3-10 female Connector
3
Air Pressure hole
Make the pressure balance
4
CH2
PA 1 Module Interface, 4.3-10 female Connector
5
CH1
PA 1 Module Interface, 4.3-10 female Connector
6
Slave OP
Connection for E2 or RU at the next higher level
7
MASTER OP
Connection for RU at the next lower level
8
Master
Indicates Master OP port operating status
9
Slave
Indicates Slave OP port operating status
10
RUN
Indicates device operating status