Lacey Act Declaration Form
Metal
Apply 1
st
Coat at a rate of 1 gallon per 50 sq.ft.
Apply 2
nd
Coat at a rate of 1 gallon per 60 sq.ft.
Single Ply – Mod. Bitumen -
Apply 1
st
Coat at a rate of 1 gallon per 40 sq.ft.
Apply 2
nd
Coat at a rate of 1 gallon per 50 sq.ft.
Concrete – Wood - Polyurethane Foam
Apply 1
st
Coat at a rate of 1 gallon per 40 sq.ft.
Apply 2
nd
Coat at a rate of 1 gallon per 50 sq.ft.
GENERAL PRODUCT INFORMATION
IMPORTANT: Where water ponding conditions
exists, roof drains or other corrective measures
must be installed to eliminate water build-ups prior
to coating the roof.
SYSTEM SPECIFICATIONS PONDING WATER
SURFACE PREPARATION
Remove all dirt, dust loose or flaking rust. Use mild
bleach solution with water to remove any mildew,
algae, or mold from surface. Surface must be power
washed to remove dirt, loose paint, excess rust, and
other foreign matter which could prevent proper
adhesion. Surface must be completely dried before
applying coating.
NOTE: This product has excellent suspension and
requires minimal stirring. Do Not Thin.
APPLICATION LIMITATIONS
Do not apply below 50° F (10°C) or when rain is
forecasted. Low temperatures and high humidity
will prolong coat dry time. Allow 4 +/- hours for
coating to dry prior to being subjected to rain.
KEEP FROM FREEZING.
AVAILABLILITY
RS003-0 250 Gal Tote
RS003-1 55 Gal Dr
RS003-2 5 Gal PL
SAFETY INFORMATION
Refer to product Material Safety Data Sheet (MSDS)
prior to product use.
WARRANTY
Max Chemical, Inc. warrant only that this product is
free of defects, since many factors which affects the
results obtained from this product (such as weather,
workmanship, equipment used and prior conditions
of substrate) are beyond our control.
CLEAN UP
Clean brushes and tools immediately after use with
warm soapy water. Completely flush all spray
equipment with this solution.
PERMA SEAL 2in1
CODE: RS003