Specifications
455 Operation Manual Page 24 6/23/98
 Composite level and/or   Verify correct equipment 
 carrier deviation too  impedances and terminations.
 high or low.   
 LCD display blank.   Loss of power. Possible 
   causes include blown fuse, 
   incorrect line voltage 
   selection, etc. (See 
   Section 2-5.) 
 LCD display shows:   A checksum error was found 
 after reading the non- 
NV Memory Error   volatile memory device. 
  The unit may still be used 
   (press the Program/Execute 
   switch to proceed) but 
   should be returned for 
  repair as soon as convenient
   since a power interruption 
  may cause loss of the unit's
   programmed settings. 
 Receiver LCD display   Receiver may be set to an 
 indicates a CXR alarm.  incorrect frequency, or the 
   transmit site may not be 
   operating on the specified 
   frequency. 
Receiver SQUELCH adjustment 
   may need to be changed. 
   (See Section 5-7) 
 The subcarrier transmitter 
   for the specified frequency
  may not be operating, or may
   be at a reduced carrier 
   level. 