Specifications
3.The software version will be displayed.
__________________
_Software Rev #.#_
__________________
4.The present status of the channel is shown.
The unit is now operational and ready for any changes the operator may desire.
3-3. CONTROL SWITCHES.
1.Program/Execute. Any change to the programming of the unit must be initiated by pressing the
Program/Execute switch and completed by pressing the Program/Execute switch.
2.Cursor Movement - Horizontal. This switch is mounted so its movement is horizontal and
moves the cursor left or right.
3.Vertical Switch. This switch is mounted so its movement is vertical and has two functions:
A)During frequency changes, the vertical movement will raise or lower the frequency
in the direction of the arrows.
B)For other functions such as on/off or compandor disable, the vertical switch will
alternately turn the function on or off regardless of the direction operated.
3-4. STATUS CHANGES.
At any time during the modification process, if you have made a mistake and do not wish to save
the changes you have made, do not press the Program/Execute switch; simply do
nothing for approximately 12 seconds, and the system will return to the normal operating
mode.
To modify the status of a channel:
1.Operate the Program/Execute switch. The display will read:
__________________
_MODIFY LOCAL _
__________________
455 Operation Manual Page 19 6/23/98