C) Commands - Table 1.1 lists the commands for the 3016-2124 and briefly describes them. After a
command is sent the 3016-2124 sends a return “>” indicating the command has been received and executed.
General Command Format - The general command format is {aaCND...}, where:
{ = start byte
aa = address (RS-485 only - option -Q)
C = 1 character, either C (command) or S (status)
N = 1 character command or status request
D = 1 character or more of data (depends on command)
} = stop byte
* PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below,
should be used ONLY when R
S-485, (OPTION-Q), is selected.
Table 1.2 3016-2124 Com
m
mands
Commands
Command Syntax* Description
Set Receiver Frequency {aaC2xxxxx} where:
• xxxxxxx = 5 characters
• Range: 21000 to 24000 kHz, in 125kHz steps
Set Receiver Gain {aaC4xx} where:
• xxx = 3 characters
• Range: 0 to 30 (0.0 dB to +30 dB, in 1.0 dB steps)
Set Spectrum Invert {aaC7x} where x =:
• 0 to disable spectrum invert
• 1 to enable spectrum invert
Enable External 10MHz IN {aaCEx} where x =:
• 0 to select Internal Reference Mode
• 1 to select External Reference Mode
• 2 to select Auto Reference Mode
Enable Remote # Just # sign
Disable Remote {aaCR0} {CR and zero}
3016-2124- Manual_Rev.0 Page 7 8/02/12