Instruction manual
B) Status Requests
Table 1.1 lists the status requests for the 2016-03 and briefly describes them.
* PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below,
should be used ONLY when R
S-485, (OPTION-Q), is selected.
TABLE 1.1 3016-2124 Statuss Requests
Status Requests
TABLE 1.1 3016-2124 Status Requests
Command Syntax* Description
Command Status {aaS1} Returns {S1bbbbbbbcccIA} where:
• bbbbbbb = Rx frequency (in kHz)
• ccc = Rx gain
• I = Spectrum invert; 1 = inverted, 0=normal
• A = summary alarm; 1 = alarmed, 0 = normal
10MHz Reference Status {aaS2}* Returns {aaS2xy} where:
• x = 0 if Internal reference mode is selected
• x = 1 if external reference mode is selected
• x = 2 if auto reference mode is selected
• y = 0 if the internal reference is active
• y = 1 if the external reference is active
3016-2124- Manual_Rev.0 Page 6 8/02/12