Instruction manual

2.4 Operation
2.4.1 Installing and Operating the 3016-2124 Downconverter
1. Connect a -50 dBm to -30 dBm signal to RF IN, J2 (Figure 2.2, page 10).
2. Connect the IF OUT, J1, to the external equipment.
3. Connect 100-240 ±10% VAC, 47-63 Hz to AC on the back panel.
4. Set the input frequency (See Section 2.5 Menu Settings, page 16).
5. Set the gain for 0.0 to +30.0 dB (See Section 2.5 Menu Settings, page 16).
6. Be sure DS6 (green, DC Power) is on and DS3 (red, Alarm) is off (Figure 2.3, page 10).
7.
AC Fuse - The fuse is a 5 mm X 20 mm, 2 amp slow blow (Type T) and is inserted in the far slot
in the drawer below the AC input as shown in Figure 2.4 below. There is a spare fuse in the near slot.
If a fuse continues to open, the power supply is most likely defective.
AC Fuse - 2 amp slow blow (Type T),
5 mm X 20 mm
FUSE DRAWER
SPARE FUSE
~
INPUT
100-240± 10%VA
C
47-63 Hz
2A MA
X
FUSE
TYPE T 2A GDC
250 VOLT
FOR 100 - 240 V~
~
FIGURE 2.4 Fuse Location and Spare Fuse