Instruction manual

2.2 Rear Panel Input/Output Signals
Figure 2.2 shows the input and output connectors on the rear panel.
PSA & PSB - POWER IN
AC input for switching
power supply.
100-240 ±10% VAC,
47-60 Hz.
J12- MONITOR &
CONTROL
DB9 female
connector.
see Table 2.1.
J11 - ETHERNET
CONNECTION
(option W8)
RJ45 Ethernet Connector
J2- RF IN
950-2150 MHz input,
-50 to -20 dBm.
see Table 2.2.
J1- RF OUT
70 MHz Output,
-20 to -10dBm.
Type F,female
J3 & J4 -
10MHz REF IN & OUT
10 MHz external
reference input (J3) and
output (J4). BNC female
connectors.
PSA
GND
J11 J12
AND
MONITOR
CONTROL
CHANNEL 4
RF IN
J10
VDC
ON
RF
J9
RF OUT
CHANNEL 3
RF IN
J8
VDC
ON
RF
J7
RF OUT
CHANNEL 1
RF IN
J2
VDC
ON
RF
J1
RF OUT 10 MHZ REF
OUTPUT
10 MHZ IN/OUT
J4
J3
10 MHZ REF
INPUT
CHANNEL 2
RF IN
J6
VDC
ON
RF
J5
RF OUT
PSB
1
5
234
6789
J5- RF OUT
70 MHz Output,
-20 to -10dBm.
Type F,female
J7 - RF OUT
70 MHz Output,
-20 to -10dBm.
Type F,female
J6- RF IN
950-2150 MHz input,
-50 to -20 dBm.
see Table 2.2.
J8- RF IN
950-2150 MHz input,
-50 to -20 dBm.
see Table 2.2.
J10- RF IN
950-2150 MHz input,
-50 to -20 dBm.
see Table 2.2.
J9- RF OUT
70 MHz Output,
-20 to -10dBm.
Type F,female
VDC on RF
Lights yellow when
+24 VDC is inserted on J1.
FIGURE 2.2 2416-x02 Rear Panel I/Os
REAR PANEL (2416-402 - Four Channel show above)
TABLE 2.1 JJ10
2.1 J10 Pinouts (RS-232C*)
Pin Function
1 Not Used
2 Rx+ (RS-232C)
3 Tx+ (RS-232C)
4 Not Used
5GND
6 Alarm Relay: Common
7 Alarm Relay: Normally Closed
8 Not Used
9 Alarm Relay: Normally Open
*Remote Serial Interface
Interface: DB-9 female
Protocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, 1 stop bit
TABLE 2.2
I
IF/RF
2.2 IF/RF Connector Optionns
Options
Option IF RF
STD BNC, 75Ω Type F, 75Ω
Bx BNC, 75Ω BNC, 75Ω
Cx BNC, 75Ω BNC, 50Ω
Dx BNC, 50Ω BNC, 50Ω
Jx BNC, 50Ω Type F, 75 Ω
Kx BNC, 50Ω BNC, 75 Ω
Mx BNC, 50Ω Type N, 50 Ω
x = # of Channels
Contact Cross Technologies for other options