Instruction manual

1.4 Setup/Testing
At the time of installation / testing the user needs to verify that the controller is properly installed and that the
'back-up' signal path and LNA are functioning properly. The 2082-14x-xx must first be properly wired to a
waveguide switch in order to perform any testing. The 2082-14x-xx will not send any waveguide switch
control signals if the unit cannot read a valid position from the waveguide switch(s). The switch position read
from the waveguide switch is displayed on the bottom line of the main LCD display screen. If “ERROR!” is
displayed then the unit cannot read a valid position.
From the optional Webpage Interface there is a Switch Position status field. If “ERROR!” is displayed in that
field then the unit cannot read a valid position.
From the optional SNMP interface there is an Object ID named switchPos2082141. If the value 99 is read
from that object ID then the unit cannot read a valid position.
The 2082-14x-xx reads the waveguide switch position through the MS connector J4 on the rear panel.
Typical waveguide switch wiring for Models 2082-141-47, 2082-141-47P, 2082-142-47 and 2082-142-47P
are shown in the following 4 diagrams:
2082-14x-47 Manual, Rev. B Page 6 12/19/13