Instruction manual

MODEL 2082-14x-47 Redundant Unit Controller
1.0 General
1.1 Equipment Description
The Model 2082-14x-47 Redundant Unit Controller is used to power, monitor and control LNA or LNB
amplifiers configured in 1:1 (2082-141-47) or 1:2 (2082-142-47) redundancy. Front panel LEDs indicate
power, status (online, standby, alarm), and mode (auto, manual, local, remote). Up to 600 ma is available to
power each amplifier and +47 VDC is provided for 1:1 (1.5A) or 1:2 (3A) waveguide switch drive. The Model
2082-141-47 has +47 volts common and the 2082-141-47P has ground common. LNA or LNB current is
measured and a fault is signaled if the current deviates from user selected thresholds. Multi-function switches
select Auto, Local, or Remote operation, priorities for 1:2, and the signal path in the Manual mode. Remote
operation via the RS232/RS485 M&C interface allows selection of priorities (1:2) and the signal path. Ethernet
is available as option, -W8, -W18, or -W28. Contact closure to ground inputs allow selection of Local/Remote,
and Auto/Manual Modes. An LCD display shows each amplifier’s current, and signal path. Form C relay
contact closures indicate amplifier and power supply status, waveguide switch position, Auto, Remote, and
Manual operation. Connectors are DB37 for contact closure I/Os, MS3112E16-23S for the amplifier plate
signals, and DB9s for monitor and control and auxiliary external contact closure alarm inputs. The 2082-14x-47
is housed in a 1RU chassis and is powered by redundant power supplies fed by separate, fused 100-240 ±10%
VAC AC input connectors.
MENU
EXECUTE
MODEL 2082
CROSS TECHNOLOGIES INC.
CONTROLLER
UNIT 1 UNIT 2
450
470
1
POWER
STATUS
STATUS
MODE
212
ALARM
STDBY
ONLINE
MANUAL
LOCAL
REMOTE
AUTO
PATH
1>1
FRONT PANEL
AC1
GND
I/O
FUSE
UNIT 1
PLATE ASSY
AC2
GND
J4
FUSE
UNIT 2
FUSE
UNIT 3
15 234
20212223
610 789
25262728
1115 121314
30313233
19 161718
242934353637
F3F2F1J1
MONITOR
AND
CONTROL
J3A
EXT
ALARM
J3B
VDC VDC VDC
DS3DS2DS1J2
15
234
6789
15
234
6789
REAR PANEL - Shown with optional Ethernet Connector (J2)
FIGURE 1.1 Front and Rear Panels
LNA
2
LNA
1
SWITCH
1
SWITCH
1
RF
IN
OFFLINE
IN
RF
OUT
OFFLINE
OUT
PLATE ASSY
2082
EXT ALARMS
MONITORS
FIGURE 1.2 Block Diagram (Upconverter Scenario)
2082-14x-47 Manual, Rev. B Page 3 12/19/13