Instruction manual

Menu 1.a
Manually set R
POS= 1>1
Toggle between switch positions with the UP/DOWN switch. Push the PROGRAM/EXECUTE switch to go to
the next menu. Use the LEFT/RIGHT switch to move the cursor to R, then push the PROGRAM/EXECUTE
switch to jump to the SAVE SETTING menu.
Menu 2
LOCAL/REMOTE=
LOCAL
R
Toggle between LOCAL and REMOTE mode with the UP/DOWN switch. Push the PROGRAM/EXECUTE
switch to go to the next menu. Use the LEFT/RIGHT switch to move the cursor to R, then push the
PROGRAM/EXECUTE switch to jump to the SAVE SETTINGS menu.
Menu 3
SET AMP1 Y/N
WINDOW
R
If “Y” is selected then the next sequence of menus prompt the user to either automatically or manually set the
high and low current values that will trip AMP1 alarm. Push the PROGRAM/EXECUTE switch to go to the
next menu. Use the LEFT/RIGHT switch to move the cursor to R, then push the PROGRAM/EXECUTE
switch to jump to the SAVE SETTINGS menu.
Menu 3a
AMP1 NOM=.XXX
AMP1 ACT=.XXX
R
This menu is simply an indication of the present value of the nominal AMP1 current, as well as the actual
measured value of AMP1 current. Press PROGRAM/EXECUTE to proceed.
Menu 3b
Set to actual
AMP1=.XXX A Y/N
R
Select “Y” to accept the presently measured value of AMP1 current as the nominal value. Select “N” to
manually enter a nominal value of AMP1 current. The nominal current value is used as a reference from which
the high and low current thresholds are derived. Push the PROGRAM/EXECUTE switch to go to the next
menu.
2082-14x-47 Manual, Rev. B Page 22 12/19/13