Instruction manual
2.5.2 Control Switches
1. Menu/Execute - Any change to the programming of the unit must be initiated by pressing the
Menu/Execute switch and completed by pressing the Menu/Execute switch.
2. Horizontal Switch - This switch is mounted so its movement is horizontal and moves the cursor
left or right.
3. Vertical Switch - This switch is mounted so its movement is vertical, and changes settings in each menu.
2.5.3 Power On Settings and LCD Menu
NOTE: The last status of a unit is retained even when power is removed. When power is restored, the unit will
return to it's previous settings.
When power is first applied, the LCD goes black to show all segments are functioning. The current firmware
version will then be displayed for approximately 2 seconds.
Power Up
REV 1.00
Normal Display
450
UNIT 1 UNIT 2
STATUS
PATH
1>1
390
The unit is now operational and ready for any changes the operator may desire. The top line displays the
current drawn by each unit. The bottom line describes the signal path and switch position. The example above
depicts a 1 for 1 unit where RF input 1 is routed through AMP1 (1>1).
Menu 1
AUTO/MAN=AUTO R
Toggle between AUTO and MANUAL mode with the UP/DOWN switch. Push the PROGRAM/EXECUTE
switch to go to the next menu. Use the LEFT/RIGHT switch to move the cursor to R, then push the
PROGRAM/EXECUTE switch to jump to the SAVE SETTINGS menu.
2082-14x-47 Manual, Rev. B Page 21 12/19/13